Reference: | 01016 |
Type: | Issue |
Product: | hHRPie 7.0 (22 April 2020) |
Title: | HR Zone Data no longer accurate after ~10 minutes |
Device: | Vivoactive 4S |
Priority: | Major |
Raised On: | 11 June 2020 19:22 |
Raised By: | dearbhailkirwan |
Status: | Open-Development-Ready-Closed |
Description: | |
When tracking an activity with hHRPie, the zone data appears accurate for ~10mins but then stays stuck on the one zone.
|
There are 2 Subscribers watching this Case.
7 older comments (click to show) | |
14 June 2020 11:17 Ddearbhailkirwan | Oh great, thanks! Im not sure how you mean - do you mean did the live HR data reported by the app appear accurate? Or are you referring to the HR chart in the recorded activity summary, or something else? |
16 June 2020 09:26 AAdmin | Thanks. I am interested to see if the App is reporting a Heart Rate during use? I''ve seen situations where the Heart Rate is recorded, but not passed onto the running Application. |
20 June 2020 19:25 Ddearbhailkirwan | Apologies for the delay, I kept forgetting to check this when training. No it looks like the heart rate reported by the app when its running gets stuck on the same number, e.g. my HR reported by the chest strap was bouncing around 160-170 and the watch app was reporting constant 117 |
22 June 2020 09:09 AAdmin | Thanks. I will contact Garmin, as it appears the Heart Rate is not being passed to the Application. I will let you know what they say. |
22 June 2020 14:33 AAdmin | Ticket raised with Garmin. Waiting for a response. |