Reference: | 00542 |
Type: | Issue |
Product: | hHRZone 5.2 (18 July 2017) |
Title: | HR graph was cleared when activity paused and started again |
Device: | Fenix 5X |
Priority: | Major |
Raised On: | 04 September 2017 18:12 |
Raised By: | author |
Resolved: | hHRZone 5.6 (05 November 2018) |
Status: | Open-Development-Ready-Closed |
Description: | |
HR graph works smoothly.
|
|
Closed: | 05 November 2018 16:12 (Fixed) |
There are 2 Subscribers watching this Case.
19 September 2017 10:33 AAdmin | Having investigated this, it is due to the watch issuing a new timer start event, in the same way the activity is started. I don't think anything can be done to separate the activity being started or resumed from a pause. The main problem is that some devices (Garmin Edge) hold data fields in memory, so this is needed to start the activity. |
05 November 2018 15:28 AAdmin | Development work to complete this case has now started. |
05 November 2018 16:12 AAdmin | Released in Version 5.6 |